Recently the topic came up on the Cisco Learning Network on OSM ratio’s for the 18/4 module.  Here is a summary of many of the ratios for various modules as well as some handy notes:

Generation 2 Switches and Modules

9216 does not support Gen-2 modules

If dedicated ports are not using all of their allocated bandwidth, the unused bandwidth is made available for use by all ports configured for shared bandwidth mode.

Performance Buffers are used on 12-port 4GB, 4-port 10GB modules only.

Port Groups

Module Ports Per Group Bandwidth Per Group Max BW Per Port Dedicated Shared
DS-X9148 12 12.8 4GB Yes Yes
DS-X9124 6 12.8 4GB Yes Yes
DS-X9304-18K9 6 12.8 4GB Yes Yes
DS-X9112 3 12.8 4GB Yes No
DS-X9704 1 10 10GB Yes No
DS-C9134-K9 4 16 4GB Yes Yes
1 10 10GB Yes No
DS-C9124-K9 4 16 4GB Yes No
DS-C9222i-K9 6 12.8 4GB Yes Yes

 

48-port Module 4:1 – 5:1
BB Credit Allocation Type BB Credit Per Module Dedicated (2-250) Shared (2-16)
ISL Fx ISL Fx
User Defined BB 6000 125 16 16 16

 

24-port Module 2:1 – 4:1
BB Credit Allocation Type BB Credit Per Module Dedicated (2-250) Shared (2-16)
ISL Fx ISL Fx
User Defined BB 6000 250 16 16 16

 

18-port Module 2:1 – 4:1
BB Credit Allocation Type BB Credit Per Module Dedicated (2-250) Shared (2-16)
ISL Fx ISL Fx
User Defined BB 4509 250 16 16 16

 

12-port Module 1:1
BB Credit Allocation Type BB Credit Per Module Dedicated (2-250)
ISL Fx
User Defined BB 5488 250 16
Performance 512 (shared) 145 12

 

With regards to the 12-port module:

There are 2488 extra buffers available as extended BB_credit buffers after allocating all the default BB_credit buffers for all the ports in ISL mode (5488 – (250 * 12)).

Extended BB_credits are allocated across all ports on the switch. That is, they are not allocated by port group.

4-port Module 1:1
BB Credit Allocation Type BB Credit Per Module Dedicated (2-250)
ISL Fx
User Defined BB 5488 250 16
Performance 512 (shared) 145 12

With regards to the 4-port module:

The ports in the 4-port 10-Gbps switching module only support 10-Gbps dedicated rate mode. FL port mode and shared rate mode are not supported.

There are 4488 extra buffers available as extended BB_credits after allocating all the default BB_credit buffers for all the ports in ISL mode (5488 – (250 * 4)).

9134 Switch
BB Credit Allocation Type BB Credit Per Port Group BB Credit Per Port Defaults (2-250)
ISL Fx
User Defined BB 64 16 16

 

9124 Switch
BB Credit Allocation Type BB Credit Per Port Group BB Credit Per Port Defaults (2-250)
ISL Fx
User Defined BB 64 16 16

 

9222i Switch
BB Credit Allocation Type BB Credit Per Port Group BB Credit Per Port Defaults (2-250)
ISL Fx
User Defined BB 4509 250 16